Replace the batteries as follows:
1. Switch off the communication unit.
2. Loosen the screw (Allen key 2 mm) on the battery cover.
3. Open the battery cover.
4. Remove the old batteries.
5. Insert new batteries as shown in the graphic on the battery
compartment.
CAUTION
!
Ensure that the battery polarity is correct. Inserting the
batteries incorrectly will cause irreparable damage to the
communication unit.
6. Check that the battery cover seal is clean and undamaged and
fitted correctly (see page 5, Fig. C). Replace the battery cover seal
if necessary.
7. Close the battery cover. Slightly lubricate the seal with silicone
grease if necessary.
8. Slightly press down the battery cover so that it fits flush to the casing,
and tighten the screw (torque: max. 0.3 Nm, see page 5, Fig. D).
9. Dispose of used batteries in accordance with applicable regulations.
5.3.2
Dismantling the communication unit from the full face mask
1. Carefully loosen the fastening eyes from the visor frame without
the use of tools.
2. Detach the communication unit from the connection piece.
3. Fit the protective cap onto the full face mask.
6

Transport

The communication unit can be transported in its original packaging.
Alternatively, it can be fitted onto the full face mask and transported
with the full face mask in a suitable transport box.
Dräger FPS-COM 7000
7

Storage

Store the communication unit in a dry, dust-free location. Keep away
from direct sunlight or heat radiation.
Storage temperature see chapter 9 on page 33
8

Disposal

This product must not be disposed of as municipal waste.
This is indicated by the adjacent icon.
You can return this product to Dräger free of charge. For
information please contact the national sales organisations
and Dräger.
Batteries and rechargeable batteries must not be disposed of
as municipal waste. This is indicated by the adjacent icon.
Collect and dispose of batteries and rechargeable batteries at
battery collection centres, in accordance with applicable
regulations.
9

Technical data

Ambient conditions
during storage: -15°C to +25°C
700 to 1300 hPa
10 to 95% rel. humidity
Protection class IP 67
Operating time Typically 8 hours,
depending on level of communication