Télécharger Imprimer la page

Parkside PARRW 20-Li A1 Traduction Des Instructions D'origine page 31

Publicité

Les langues disponibles
  • FR

Les langues disponibles

  • FRANÇAIS, page 38
• Always hold the device with both
hands to avoid touching the cleaning
spiral.
• Do not set the direction of rotation
switch (4) to L unless the cleaning spir-
al is blocked or jammed in a pipe.
• Check that the pipe size is suitable for
the dimensions of the cleaning spiral
(Technical data, p. 23).
• If necessary, dismantle the siphon to
have better access to the blockage.
• Check that the plug (9a) of the drain
hole (9) is closed and tightened.
LED work light (10) (Fig. C)
The device is equipped with an LED work
light to illuminate the direct work area.
• The LED work light illuminates as soon
as the device is switched on.
• The LED work light remains on for ≈ 5
seconds after the device is switched off.
Inserting and removing the
battery
 WARNING! Risk of injury due to
unintentional start-up. Only insert the re-
chargeable battery into the device once
the device is fully prepared for use.
NOTICE! Risk of damage! An incorrect
battery can damage the device and bat-
tery.
Inserting the battery
1. Push the battery (12) along the guide
into the battery holder (7).
You will hear the battery click into
place.
Removing the battery
1. Press and hold the battery release (11)
on the battery (12).
2. Pull the battery out of the battery hold-
er (7).
Switching on and off
 WARNING! Risk of injury due to un-
intentional continuous operation of the
tool. Before inserting the batteries into
the unit, check that the on/off switch (5)
works properly and returns to the off posi-
tion when released.
Switching on
1. Insert the rechargeable battery (12) in-
to the tool.
2. Select the direction of rotation with the
rotation direction switch (4).
3. Press and hold the On/off switch (5).
The LED work light (10) lights up.
Switching off
1. To turn it off, release the on/off switch
(5).
2. Wait until the power tool has stopped
before placing it down.
3. When taking a break: Set the direc-
tion of rotation switch (4) to the centre.
These safety measures prevent acci-
dentally starting the power tool.
4. Remove the rechargeable battery (12)
from the device if you are leaving the
device unattended or if you have fin-
ished working.
Cleaning procedure
Working on a blocked pipe
To clear a blockage, work with the clock-
wise rotation. The cleaning spiral is twis-
ted into the blockage like a corkscrew and
sticks to it. Blockages that do not stick to
the cleaning spiral are loosened from the
pipe by the rotation of the cleaning spiral.
Notes
Correct distance to the pipe opening:
• Hold the device far enough away from
the pipe opening so that you can ob-
serve the cleaning spiral (1) during op-
eration.
• Maximum distance: 15 cm
GB
MT
31

Publicité

loading