OPERATION
NOTE: Make sure both units have been shut down and
there are no devices connected to the outlet receptacles.
NOTICE
Arrange the generators in a "V" shape
to allow the heat from the exhaust to safely escape.
The exhaust heat from one unit may discolor or melt
the plastic case of the other unit if positioned too close-
ly together.
To install the parallel cable:
l Insert the cable end into one of the parallel ports on the
first unit. Insert the other end of the same cable into the
corresponding port on the second unit.
l Repeat steps with the other cable.
NOTE: It is important to connect both ends of the cable to
the same ports on both generators. Make sure the same
cable ends are connected to the same port on each gener-
ator before starting the generators.
Start one generator at a time. Wait for the first unit to run
at a stable idle before starting the second unit. Connect
one device at a time and allow the unit to stabilize before
connecting the next device.
CARE AND MAINTENANCE
WARNING
the spark plug boot (see figure 17) from the spark plug
when performing maintenance on the generator.
WARNING
with recommended or equivalent replacement parts.
Using an incorrect or incompatible part might create a
hazard that could result in serious personal injury.
WARNING
30 minutes before performing any maintenance pro-
cedure.
WARNING
or gasoline. Wear protective clothing and equipment.
Wash all exposed skin with soap and water. Prolonged
skin contact with gasoline or engine oil may cause se-
vere skin irritation and other adverse reactions.
22 | English
Accidental start-up. Disconnect
Replace damaged or worn items
Allow hot components to cool for
Avoid skin contact with engine oil
To remove the parallel cable:
l Remove all devices from the generator's receptacles.
l Shut down both of the connected generators.
l Remove the parallel cable ends from the generator ports.
TRANSPORTING
l Turn off the generator.
l Allow the generator to cool a minimum of 30 minutes
before transporting.
l Replace all protective covers on the generator control
panel.
l Only use the generator's fixed handle to lift the unit or at-
tach any load restraints such as ropes or tie-down straps.
DO NOT attempt to lift or secure the generator by holding
onto any of its other components.
l Keep the unit level during transport to minimize the pos-
sibility of fuel leakage or, if possible, drain the fuel or run
the engine until the fuel tank is empty before transport.
CAUTION
generator or place it on its side. Fuel or oil can leak
and damage to the generator may occur.
NOTICE
Check the physical condition of the
product prior to each use. Look for loose bolts, fluid
leaks, and other signs of wear. Replace all damaged
items. For replacement parts or assistance, contact
our customer service team.
To prolong the life of this product, follow the care and mainte-
nance instructions in this section. Contact customer service
before servicing any recall or warranty parts.
CLEANING THE GENERATOR
Do not store or operate your generator in dirty, dusty, or
corrosive environments. Do not allow foreign materials and
debris to clog the vents on the unit.
NEVER clean the generator with a garden hose. Water can
damage the generator's fuel system and electrical compo-
nents. If the unit needs to be cleaned, use a soft brush and
damp cloth to clean the exterior and use low pressure air
(no greater than 25 psi) to clean the vents.
Never use gasoline as a cleaning agent.