Preliminary conditions:
-
Load limiter correctly mounted and
DE
wired.
NL
-
Adjustment screws unscrewed to the
ES
maximum.
IT
-
Hook free of any load.
PT
Equipment required:
GR
-
A load (called "WLL") equivalent to
NO
100%
SE
authorized for the lifting machine.
FI
-
An additional load equivalent to 10%
of the "WLL".
DK
-
A load "X" equivalent to the value of
PL
the "Wire rope slack" threshold.
RU
12
of
the
nominal
capacity
ACTIONS
The additional 10 % represents
Lift the two loads
the overshoot value authorized
1
(100 % + 10 % WLL)
in accordance with the
by about 10 cm.
European directives.
Gradually screw in the
threshold adjustment screws
Adjust the safety
(rep 3) until the NC contact
2
threshold S1.
opens (§4.4). Use a
multimeter, for example, to
check the state of the contact.
It must be possible to lift the
"WLL" load.
It must be possible to lift the
"WLL" load + 10 %.
Depending on the lifting speed,
Check correct
the dynamic effect may
3
operation.
produce an unintentional
overload. In this case, consult
with a technician capable of
integrating a signal filtering
device (example: time-out,
etc.).
Lift the intermediate
Wait for the load to stabilize
4
load "X"
before adjusting the threshold.
Gradually screw in the
threshold adjustment screws
(rep 3) until the NO contact
opens (§4.4).
Adjust the safety
For more accuracy, take into
5
threshold S2.
account the hysteresis in the
setting.
Use a multimeter, for example,
to check the state of the
contact.
Check that the micro switch for
Check correct
threshold S2 trips when the
6
"Wire rope slack" condition is
operation.
reached.
6.
Maintenance
verification
Tractel® recommends to periodically check
correct operation of the load limiter and the
accuracy
of
the
accordance with the application regulations.
No special maintenance is required for this
type of device. When performing periodic
inspection, check that the connecting cable to
the control circuit is properly secured and is in
good condition.