Installation and operating instructions Wilo-Flumen OPTI-TR 20-1, 28-1, 30-1, 40-1 Wilo-Flumen EXCEL-TRE 20, 30, 40
Appendix
Connection values: max. 250 V(AC), 2.5 A, cos φ = 1
▪ Connect the PTC sensor via an evaluation relay. Relay "CM-MSS" is recommended for
this. The threshold is preset.
▪ Connect the external pencil electrode via an Ex-rated evaluation relay! Relay "XR-4..." is
recommended for this.
The threshold is 30 kOhm.
▪ The connection must be made using an intrinsically safe circuit!
▪ Type of converter: Pulse-width modulation
▪ Continuous duty: 30 Hz up to rated frequency (50 Hz or 60 Hz).
▪ Min. switching frequency: 4 kHz
▪ Max. overvoltages on the terminal board: 1350 V
▪ Output current on the frequency converter: max. 1.5 times rated current
▪ Max. overload time: 60 s
▪ Torque applications: quadratic curve
Speed/torque curves required are available on request!
▪ Observe additional measures with regard to EMC regulations (choice of frequency con-
verter, filters, etc.).
▪ Never exceed the rated current or rated speed of the motor.
▪ It must be possible to connect the motor's own temperature monitoring (bimetallic
strip or PTC sensor).
▪ If the temperature class is marked as T4/T3, temperature class T3 applies.
DANGER
Risk of explosion when using non-Ex-rated mixers!
Risk of fatal injury due to explosion! Only use mixers which have Ex labelling on the
rating plate within potentially explosive areas.
▪ The operator is responsible for defining the potentially explosive area.
▪ Only Ex-rated mixers may be used within potentially explosive areas.
▪ Mixers with an Ex rating must be labelled as such on the rating plate.
▪ Do not exceed the max. fluid temperature!
▪ According to DIN EN 50495, a safety device with SIL level 1 and hardware fault toler-
ance 0 must be provided for category 2.
▪ Carry out maintenance tasks according to the regulations.
▪ Only carry out maintenance tasks mentioned in these installation and operating in-
structions.
▪ The spark-proof gaps may only be repaired according to the manufacturer's design
specifications. It is not permitted to carry out repairs according to the values in tables 1
and 2 of DIN EN 60079-1.
▪ Only use screw plugs as stipulated by the manufacturer, that at least correspond to a
strength class of 600 N/mm² (38.85 long tons-force/inch²).
The paint layer can become electrostatically charged in case of thicker
coats.DANGER! Risk of explosion! In explosive atmospheres, a discharge can cause
an explosion!
If the housing coating has to be repaired, the maximum coat thickness is 2 mm
(0.08 in)!
Changing the connection cable is strictly prohibited!
Changing the seal on the motor side is strictly prohibited!