Lenze starttec 1 Instructions De Montage page 87

Table des Matières

Publicité

Les langues disponibles

Les langues disponibles

Show/Hide Bookmarks
Menu u u u u s s s s e e e e r r r r - The 10 most important drive parameters
After mains switching or plugging in the hand terminal during operation, the 10 codes defined to be
the most important in the user menu user (Code C0517) are available immediately.
In default setting the menu user contains all codes required for a standard application:
Code
Name
C0054 Apparent motor 1 current
C0055 Apparent motor 2 current
C0006 Changeover HW/hand
terminal
C0120 Rated current
1 Motor 1
2 Motor 2
C0410 Configuration digital input
signals
1 Motor 1 start/stop
2 Motor 2sStart/stop
3 Brake control
4 ... 24
C0415 Digital output signal
configuration
1 X3/A1
2 X3/A2
3 X3/A3
4 X3/A4
5 ... 6 AS-i output bit
C0012 Acceleration time - motor
voltage
1 Motor 1
2 Motor 2
C0423 Delay time "Brake release"
C0424 Delay time "Brake
activation"
C0002 Parameter set management
L
Lenze setting
Only display
Only display
0
Setting of acceleration time (C0012) and initial voltage
(C0016) via potentiometer, setting of the rated motor
current (C0120) via step switch
Rated motor current for I
Accepts value of step switch:
If C0006 = 0, 2, 4, 6:
l
– Only display
– Only display
If C0006 = 1, 3, 5, 7:
l
– Rated current adjustable under C0120
1
X3/E1
2
X3/E2
3
X3/E3
255
not assigned
3
Status Motor 1
4
Status Motor 2
5
Brake status
25
TRIP fault message
255
not assigned
Time vor voltage change U
Accepts the value of potentiometers "T"
If C0006 = 0, 1, 2, 3:
l
– Only display
– Only display
If C0006 = 4, 5, 6, 7:
l
– Acceleration time adjustable via C0012
0.00 s
0.00 s
See code table
EDK71MMXXX-010 DE/EN/FR 2.0
Commissioning
With hand terminal
2
t monitoring
... U
0
mains
7
87

Publicité

Table des Matières
loading