Show/Hide Bookmarks
(
Stop!
Connect the mains cable in phase.
If the mains phases are mixed up, the following error message will appear: Er252
(a) or Er253 (e).
3/N/PE AC 100 ... 550 V
45 ... 65 Hz
L1
L2
L3
N
PE
L1 L2 L3
1U
1V
-X1
M
3~
ϑ>
M
3~
Terminal
Function (bold = Lenze setting)
L1, L2, L3
Mains connection
1U, 1V, 1W Motor 1 connection
B1, B2, BN Connection of Lenze spring operated brake BFK457 or
BFK458
X3/59
Connection of supply voltage +24 VDC
Reference: X3/7
X3/20
DC voltage output + 24 VDC
Reference: X3/7
X3/7
Reference potential
L
0.4 Nm
3.5 lb-in
≤
1.5 mm
≥
AWG 16
X3
BN
2U
1W
2V
2W
B1 B2
PTC
EDK71MMXXX-010 DE/EN/FR 2.0
Electrical installation
2
6mm
X3
20 28
20
E1
E2 E3 E4 E5
X3
X3
T1 T2
A+ A-
}
+
∅ 4.3 mm
Connection diagram
+24 V DC
(+18 VDC - 0 % ... +30 VDC + 0 %,
200 mA ... 1.5 A)
+
Z Z Z Z
20
7
7
A1 A2 A3 A4
7 59 59
3.4 Nm
30 lb-in
Data
Cab e c oss sect o
Cable cross section:
2
2
max. 4 mm
(AWG 10)
^ 77
+18 VDC - 0 % ... +30 VDC + 0 %)
min. 200 mA
max. 1.5 A (all inputs and outputs
assigned)
+18 VDC ... +30 VDC
max. 500 mA
5
-
7 7
GND
77
start025
75