Technical data
2

Rated data

Supply voltage
Voltage range
Current consumption at + 24 VDC
Current consumption at + 24 VDC
Motor switch
Mains voltage
(applied voltage)
Max. continuous output current
Cyclic switching
Motor power (Lenze motors)
with 3(/N)/PE AC 400 V P
with 3(/N)/PE AC 500 V P
Brake switch
Output voltage
with 3(/N)/PE AC 400 V V
with 3(/N)/PE AC 500 V V
Max. output current
Cyclic switching
Monitoring functions
Motor protection switch function
Mains failure detection
Load failure detection
68
V
DC
V
r
I
r
with 3/PE AC 230 V P
r
r
r
with 3/PE AC 230 V V
B
B
B
I
B
Motor temperature
Controller protection
EDK71MMXXX-010 DE/EN/FR 2.0
+ 24 VDC (+18 VDC - 0 % ... +30 VDC + 0 %)
min. 200 mA
max. 1.5 A (digital input and outputs fully assigned)
3/PE AC 100 V - 0 % ... 550 V + 0 %; 45 Hz - 0 % ... 65
Hz + 0 %
9.5 A (sum of output currents)
max. 1 / s
0.25 ... 2.2 kW
0.25 ... 4.0 kW
max. 9.5 A
max. 9.5 A
0.37 ... 5.5 kW
205 VDC
180 VDC, 205 VDC
257 VDC
0.4 A
max. 3 / s
2
I
t monitoring, activation class can be set
2
(I
t-activation characteristic: ^ 69 )
Class 10A
max. I
Class 10
max. I
Class 20
max. I
Class 30
max. I
PTC thermistor or thermostat (NC contact)
2
I
t-monitoring (class 10A) ref. to 9.5 A
yes
yes, switch off limit programmable
= 9.5 A
r
= 9.0 A
r
= 8.0 A
r
= 7.0 A
r
L