Show/Hide Bookmarks
Commissioning
7
Code table
Code
No.
Name
C0410
Configuration
digital input
v
signals
u u u u S S S S E E E E r r r r
1 Motor 1
1 Motor 1
start/stop
t t/ t
2 Motor 2
start/stop or
start/stop or
direction of
rotation
3 Brake control
3 Brake control
4 Reserved
...
9 Reserved
10 starttec
inhibited/enable
inhibited/enable
d
11 External error
te a e o
12 Error reset
13 Reserved
...
16 Reserved
17 Reserved
ese ed
18 Reserved
...
24 Reserved
102
Possible settings
Lenze
Selection
Linkage of external signal sources
to internal digital signals
1
1
Digital input X3/E1
Digital input X3/E1
2
Digital input X3/E2
3
3
Digital input X3/E3
Digital input X3/E3
255
Not assigned
Not assigned
255
255
Not assigned
255
55
Not assigned
ot ass g ed
255
Not assigned
255
Not assigned
Not assigned
255
255
55
Not assigned
ot ass g ed
255
Not assigned
Not assigned
255
EDK71MMXXX-010 DE/EN/FR 2.0
IMPORTANT
Motor 1 start
HIGH
Motor 1 stop
LOW
Motor 2 start or
HIGH
CCW rotation
Motor 2 stop or
LOW
CW rotation
Brake release
HIGH
Brake activation
LOW
starttec enable
HIGH
starttec inhibit
LOW
No error
HIGH
External error
LOW
active
LOW-HIGH-transition resets
error
L

Publicité