Show/Hide Bookmarks
Commissioning
7
Code table
Code
No.
Name
C0415
Digital output
signal
v
configuration
u u u u S S S S E E E E r r r r
1 Digital output
1 Digital output
X3/A1
X3/A1
2 Digital output
X3/A2
X3/A2
3 Digital output
X3/A3
X3/A3
4 Digital output
4 Digital output
X3/A4
X3/A4
5 AS i status bit
5 AS-i status bit
D0
6 AS-i status bit
6 AS i status bit
D1
C0415
C0 5
v
u u u u S S S S E E E E r r r r
S S S S E E E E
(cont )
(cont.)
104
Possible settings
Lenze
Selection
Output of internal digital signals to
terminals or AS interface
3
3
Status Motor 1
Status Motor 1
4
Status motor 2 or direction of
rotation
rotation
5
Brake status
25
25
Error message TRIP
Error message TRIP
255
255
Not assigned
Not assigned
255
255
Not assigned
Not assigned
Internal digital signals
0
Not assigned
1
Reserved
2
Reserved
3
Status Motor 1
4
Status Motor 2
5
Brake status
6
Error in power stage
7
Reserved
8
starttec enabled/inhibited
9 ...
Reserved
12
13
Warning "Overtemperature"
14; 15 Reserved
16
Ready for operation
17; 18 Reserved
19
Warning "Motor overtemperature"
(PTC input)
EDK71MMXXX-010 DE/EN/FR 2.0
IMPORTANT
Motor 1 is running HIGH
Motor 1 has been
LOW
stopped
Motor 2 is running
HIGH
or CCW rotation
Motor 2 has been
LOW
stopped or CW
rotation
Brake has been
HIGH
released
Brake actviated
LOW
TRIP active
HIGH
No error
LOW
Only active with variant
Only active with variant
E71MM402FXAXXX
Only generated if
C0119 = 2
L