Show/Hide Bookmarks
Troubleshooting
?
Error messages
Display
Fault
1)
Keypad PC
53
Motor temperature
O O O O H H H H 3 3 3 3
too high (PTC or
a
thermal contact
tripped)
(only generated if
C0119 = 1)
203
O O O O H H H H 5 5 5 5 1 1 1 1
e
72
PAR1 transmitted
P P P P r r r r 1 1 1 1
incorrectly
a
79
Internal fault
P P P P r r r r 5 5 5 5
a
81
Time error during
P P P P t t t t 5 5 5 5
parameter set
a
transfer
76
Faulty auto-TRIP
r r r r S S S S t t t t
reset
a
1)
LECOM error number
110
Cause
Motor too hot because of
l
impermissibly high currents
or frequent excessively long
acceleration processes
No PTC or thermal contact
l
connected to X3/T1 and
X3/T2
PAR1 is faulty
Data flow interrupted by hand
terminal or PC, e. g. hand
terminal removed during data
transfer
More than 8 fault messages in
10 minutes
EDK71MMXXX-010 DE/EN/FR 2.0
Remedy
Check drive selection
l
Connect PTC or thermal contact
l
or switch off monitoring
Repeat data transfer or load Lenze
setting before enabling the controller
Contact Lenze
Repeat data transfer or load Lenze
setting before enabling the controller
Depends on the fault message