ELECTRICAL CONNECTION
Caution - warning
The connection must be made by authorised, skilled personnel, in accordance
with the relevant legal requirements, using appropriate and specified materials.
The appliance is supplied with operating voltage 400V/3N/PE, which can be
switched to 230V/3/PE (see attached wiring diagrams).
Before doing any work, cut off the mains electricity supply.
Connect the appliance to the mains electricity supply
as follows.
1 – If not already present, install an automatic circuit-
breaker (B), close to the appliance, with the following
characteristics.
– Thermal-magnetic device (to adjust see table on
page 4)
– Class B or C (IEC 898)
– Differential breaker set at 30 mA
2 – Undo the screws and remove the side panel (A).
3 – Connect the automatic circuit-breaker (B) to the
appliance's terminal board (C) and to the electrical
mains supply, in accordance with the electrical sys-
tem diagram provided at the back of the manual and
using a cable with the following characteristics.
– Weight:
than H05RN-F type (designation 245 IEC 57)
– Temperature of use:
Important
When connecting, take care to connect the neutral and earth lines.
4 – Replace the panel (A) and retighten the screws when the operation is complete.
CONVERSION OF ELECTRICITY SUPPLY (FX 82 E2T)
To carry out this operation, proceed as follows.
1 – Disconnect the mains electricity supply.
2 – Undo the screws to remove the side panel (A).
IT
3 – Fit the jumper (B) to make the electrical connection
GB
of the terminals (C-D) (see attached wiring diagrams).
4 – Use lever (E) to set the overload cutout to 4 A.
DE
FR
ES
English
70°C.
C
B
C
E
- 26 -
B
A
IDM-39617701600.tif
A
D
IDM-39617701700.tif
Use and installation manual