2.6 - CONFIGURATIONS THROUGH THE CONTROL PANEL
To change configurations, proceed as follows:
a.
Insert the plug into the power socket to feed the air conditioner, then make sure
the latter is set to stand-by mode.
b.
Keep the MODE key pressed for approximately 10 seconds until the display
shows the parameter
c.
Press the + or - keys to select the parameter value to be set (from P0 to P4).
d.
Keep the MODE key pressed for approximately 2 seconds until the parameter
flashes.
e.
Press the keys + or - to select the desired value.
f.
Press MODE to confirm the desired value.
g.
Press the Standby key or wait approximately 20 seconds to leave the parameters
configuration procedure.
2.6.1 - C onfiguration of the electronics for low or high wall installation
The unit can be installed both in the lower part (adjacent to the floor) and in the upper
part (adjacent to the ceiling) of the wall.
To optimize air distribution and ambient comfort, the direction of the air flow can be
changed by changing the position of the air outlet flap.
Upper wall configuration determines an automatic correction of
the room temperature equal to 3°C in heating mode.
For correct functionality, each modification of the configuration of
the air outlet flap must correspond to the relative modification of
the electronic configuration.
In the configuration of high or low wall installation, the display shows 1
To set the desired configuration, carry out the previously described procedures and
choose between the parameter
2.6.2 - Energy boost/System enable
configuration
The inlet located on the clamp
(Y2) of the main board (Y1) can
be used to activate the ENERGY
BOOST or SYSTEM ENABLE
functions of the air conditioner
(fig. 29).
.
(for roof installation) or
29
Y1
Y3
Y2
.
(for floor installation).