OPERATION
DATA CENTER
See Figure 14.
Push the mode button to cycle through the data display
modes.
Voltage: Displays current voltage output.
Frequency (Hz): Displays power output frequency in Hertz.
Lifetime Hours: Displays the lifetime run hours.
Run Time/Maintenance: Displays current run time. Resets
to zero when shut down. Maintenance reminder displayed
when required.
Maintenance Codes:
P25 - Change engine oil
P50 - Clean air filter, Change engine oil
P100 - Change engine oil, clean air filter, replace fuel
filter
BREAK-IN PERIOD
For proper break-in, do not exceed 50% of the rated running
watts during the first five hours of operation.
Use supplied oil until first recommend oil change. Do not
use full synthetic oil during break in period. Full synthetic oil
may prevent proper breaking and seating of the piston rings.
Vary the load occasionally to allow stator windings to heat
and cool and help seat the piston rings.
BEFORE STARTING THE GENERATOR
Verify that:
l The generator is placed in a safe, appropriate location.
l The generator is on a dry, flat, and level surface.
l Oil and fuel levels are within safe operating range.
l All loads are disconnected from the control panel recep-
tacles.
DANGER
NOT move or tip the generator during operation.
STARTING THE GENERATOR
See Figures 15 - 18.
l Place the generator in a safe, appropriate location.
l Unplug all loads.
l Check oil and fuel levels. If needed, add fuel or oil as
described earlier.
l Turn the fuel valve to the open position.
To start the generator using the recoil handle:
l Verify that the engine control switch is in the RUN (I)
position.
NOTE: The engine control switch will automatically return
to the RUN (I) position if it is not held in the START (II) or
STOP (O) position.
18 | English
Fire and explosion hazard. DO
FIG. 14
A
C
A - Voltage
B - Frequency
C - Lifetime Hours
D - Run Time/Maintenance Reminder
E - Mode Button
FIG. 15
B
A
A - Fuel Valve (Open)
B - Fuel Valve (Closed)
l Move the choke to the off/cold start position.
NOTE: If you are re-starting the generator, move the
choke to the on/warm start position.
l Firmly grasp and pull the recoil handle slowly until you feel
increased resistance. At this point, pull the recoil handle
rapidly away from the generator until the engine starts.
NOTE: Gently return the recoil handle into place after
starting the unit. Do not let it snap back against the unit.
During initial starting, additional pulls may be required to
prime the fuel pump.
l After the engine starts, move the choke to the on/warm
start position.
E
B
D