OPERATION
CIRCUIT BREAKERS
See Figure 19.
The 20 amp circuit breaker protects devices and equipment
connected to the 120V, 20 amp receptacles from electrical
overload. The main circuit breaker will automatically switch
OFF if the combined load of the receptacles exceeds the
generator's capacity. If a circuit breaker activates, turn off
the connected device, remove it from the port or outlet, and
reset the circuit breaker.
TRANSPORTING
l Turn off the generator.
l Allow the generator to cool a minimum of 30 minutes
before transporting.
l Replace all protective covers on the generator control
panel.
l Always use the generator's frame, not the handle, to lift
the unit or attach any load restraints such as ropes or
tie-down straps. DO NOT attempt to lift or secure the
generator by holding onto any of its other components.
l Keep the unit level during transport to minimize the pos-
sibility of fuel leakage or, if possible, drain the fuel or run
the engine until the fuel tank is empty before transport.
MAINTENANCE
WARNING
the spark plug boot (see figure 21) from the spark plug
when performing maintenance on the generator.
WARNING
with recommended or equivalent replacement parts.
Using an incorrect or incompatible part might create a
hazard that could result in serious personal injury.
WARNING
30 minutes before performing any maintenance pro-
cedure.
WARNING
or gasoline. Wear protective clothing and equipment.
Wash all exposed skin with soap and water. Prolonged
skin contact with gasoline or engine oil may cause se-
vere skin irritation and other adverse reactions.
20 | English
Accidental start-up. Disconnect
Replace damaged or worn items
Allow hot components to cool for
Avoid skin contact with engine oil
FIG. 19
B
A
A - Main Circuit Breaker
B - 120/240 Volt AC 30 Amp Receptacle
C - 120 Volt AC 20 Amp GFCI Receptacles
D - 20 Amp Circuit Breakers
CAUTION
generator or place it on its side. Fuel or oil can leak
and damage to the generator may occur.
NOTICE
Check the physical condition of the
product prior to each use. Look for loose bolts, fluid
leaks, and other signs of wear. Replace all damaged
items. For replacement parts or assistance, contact
our customer service team.
To prolong the life of this product, follow the maintenance
instructions in this section. Contact customer service before
servicing any recall or warranty parts.
CLEANING THE GENERATOR
Do not store or operate your generator in dirty, dusty, or
corrosive environments. Do not allow foreign materials and
debris to clog the vents on the unit.
NEVER clean the generator with a garden hose. Water can
damage the generator's fuel system and electrical compo-
nents. If the unit needs to be cleaned, use a soft brush and
damp cloth to clean the exterior and use low pressure air
(no greater than 25 psi) to clean the vents.
Never use gasoline as a cleaning agent.
C
C
D
D
Fire hazard. DO NOT up-end the

Publicité