OPERATION
To start the generator using the engine control
switch:
l .Move the choke to the on/warm start position.
l Push and hold the engine control switch in the START
(II) position for two seconds.
NOTE: If the engine control switch does not start the
generator, the generator's battery may need to charge.
Start the unit using the recoil handle. The generator's
battery will charge as the unit runs.
NOTE: The engine control switch will automatically return
to the RUN (I) position if it is not held in the START (II) or
STOP (O) position.
To add loads after starting the generator:
l When the generator output stabilizes, you can safely
connect loads to the control panel receptacles.
NOTE: Verify that all devices are turned off before con-
necting them to the generator.
NOTE: Make sure that the wattage requirements for
all connected devices are in line with your generator's
capabilities.
l Connect and start the largest device or appliance.
l Allow the generator output to stabilize. Once stable, the
engine should run smoothly, and the device should function
properly.
l Connect and start the next largest device or appliance.
l Allow the generator output to stabilize.
l Repeat this process for each additional load.
STOPPING THE GENERATOR
See Figures 15 - 16.
l Remove any connected loads from the control panel
receptacles.
l Allow the generator to run at "no load" to reduce and
stabilize engine and alternator temperatures.
l Push and hold the engine control switch in the
STOP (O) position for one second to stop the generator.
NOTE: The engine control switch will automatically return
to the RUN (I) position if it is not held in the START (II) or
STOP (O) position.
l Turn the fuel valve to the closed position.
To stop the unit quickly in an emergency:
l Push and hold the engine control switch in the
STOP (O) position for one second to stop the generator.
FIG. 16
A
B
A - Engine Control Switch in START (II) Position
B - Engine Control Switch in RUN (I) Position
C - Engine Control Switch in STOP (O) Position
FIG. 17
A
A - Choke (Off/Cold Start)
B - Choke (On/Warm Start)
FIG. 18
A - Recoil Handle
C
B
A