Technical Specifications; Information According Regulation (Eu) 66/2014; Hob Power Configuration - ETNA KI390ZT Mode D'emploi

Table des Matières

Publicité

Les langues disponibles

Les langues disponibles

TECHNICAL SPECIFICATIONS

Information according regulation (EU) 66/2014

Measurements according EN60350-2
Model identification
Type of hob
Number of electric cooking zones and/or areas
Heating technology
For circular electric cooking zones: diameter of useful surface area per
electric heated cooking zone in cm
Energy consumption per cooking zone or area calculated per kg (EC
) in Wh/kg
hob
Energy consumption for the hob, calculated per kg (EC
in Wh/kg

Hob power configuration

The hob connecting power can be adjusted according to the power supply network.
Default factory setting is a 3 phase connection. When connecting to a 2 phase network the hob
power needs to be limited.
Adjust the hob power limitation
1. Touch and hold the timer key within 2 minutes after connection to the power mains.
2. Touch the minus (-) key while holding the timer key. You hear a audio signal.
3. Touch the front left cooking zone plus (+) key while holding the timer key.
The front left cooking zone display show symbol (C).
The rear left cooking zone display show the limitation zero (0) or one (1).
Configuration
C0 = 0
C0 = 1
4. Touch the front left plus (+) key to change the power limitation.
5. Touch the minus (-) key and then the On/Off key to confirm the setting.
EN 20
Power limitation
10400 W
7400 W
electric
)
electric cooking
Network connection
3 phase
2 phase
KI390ZT
Induction hob
5
Induction cooking
zones and cooking
areas
17.5
21.5
26.7
185.0 166.8 183.5
177.4

Publicité

Table des Matières
loading