TECHNICAL SPECIFICATIONS
Information according regulation (EU) 66/2014
Measurements according EN60350-2
Model identification
Type of hob
Number of electric cooking zones and/or areas
Heating technology
For circular electric cooking zones: diameter of useful surface area per
electric heated cooking zone in cm
Energy consumption per cooking zone or area calculated per kg (EC
) in Wh/kg
hob
Energy consumption for the hob, calculated per kg (EC
in Wh/kg
Hob power configuration
The hob connecting power can be adjusted according to the power supply network.
Default factory setting is a 3 phase connection. When connecting to a 2 phase network the hob
power needs to be limited.
Adjust the hob power limitation
1. Touch and hold the timer key within 2 minutes after connection to the power mains.
2. Touch the minus (-) key while holding the timer key. You hear a audio signal.
3. Touch the front left cooking zone plus (+) key while holding the timer key.
The front left cooking zone display show symbol (C).
▷
The rear left cooking zone display show the limitation zero (0) or one (1).
▷
Configuration
C0 = 0
C0 = 1
4. Touch the front left plus (+) key to change the power limitation.
5. Touch the minus (-) key and then the On/Off key to confirm the setting.
EN 20
Power limitation
10400 W
7400 W
electric
)
electric cooking
Network connection
3 phase
2 phase
KI390ZT
Induction hob
5
Induction cooking
zones and cooking
areas
17.5
21.5
26.7
185.0 166.8 183.5
177.4