2. Turn the winch handles (A, Figure 17) until the tower is
fully raised. Do not overturn the handles.
Lowering the Light Tower
1. Turn the winch handles (A, Figure 17) until the tower is
fully lowered. Do not overturn the handles.
17
Operating the Tower Lights
WARNING
Looking at illuminated light fixtures could result in serious
injury. Never look directly at illuminated light fixtures.
Turning the Lights On
1. Unlock and open the control compartment cover.
2. Turn the circuit breaker for the chosen power inlet to the
ON position. See Preparing to Operate the Unit.
3. Select the preferred mode of operation: Timer / Manual or
Photocell. See Light Operation Mode.
4. Turn the individual light switches (A, Figure 18) (1-4) to
the ON position (if set to OFF).
Note: If the mode of operation is set to Photocell or Timer,
the lights will not turn on until dark (Photocell) or until the time
selected (Timer).
Turning the Lights Off
• If in Manual mode, turn Manual mode off. See Light
Operation Mode.
• If in Photocell or Timer mode, the lights will turn off
automatically in ambient light (Photocell) or at the time
selected (Timer).
16
18
Light Operation Mode
The tower lights can be controlled manually, by photocell, or
by timer.
Manual Operation
1. Turn the Photocell / Timer switch (A, Figure 19) to the
TIMER position.
2. Push the OVR button (G, Figure 20) on the timer module
to turn on Manual mode. Push again to turn off.
Photocell Operation
Turn the Photocell / Timer switch (A, Figure 19) to the
PHOTOCELL position. The lights will automatically come on
in the absence of ambient light.
Note: For most consistent operation, avoid locating the unit in
a shadowed area, and orient the unit so the control box faces
north.
Timer Operation
Turn the Photocell / Timer switch (A, Figure 19) to the TIMER
position.
To set the timer:
1. Reset the timer module (first time use):
a. With a blunt object press and release the Reset
button (I, Figure 20). The timer screen (C) will flash.
b. Press the Clock (A, Figure 20) and Hour (E) buttons
simultaneously. The time will reset to 12:00am.
2. Set the clock:
a. If currently in Daylight Savings Time, press the +1h
button (H, Figure 20). (If not, bypass this step.)
b. Press and hold the Clock button (A, Figure 20) while
simultaneously pressing the Day (D), Hour (E) and /
or Minute (F) buttons until the correct day and time
appears.
3. Set the Timer
• Timer On:
• Press the Timer button (B, Figure 20) once. ON
will appear to the left of the display.