Mounting and
operating instructions
8.5.19
Measured operating values
Command (Byte 3): decimal 73; hexadecimal 0x49
Parameter:
no
Reply (Byte 3):
decimal 89; hexadecimal 0x59
Parameter:
Data
The current measured values and switching output recognition are read whilst taking into account the settings which
alter the characteristics (4 mA point, 20 mA point, Min., Max., autom. centre ...).
Example telegram
(in the example, the sensor has the address 1)
Master telegram
Designation
1. Byte
Address
2. Byte
Length
3. Byte
Command
4. Byte
Check sum
8.5.20
Fast measured value output
Command (Byte 3): decimal 70; hexadecimal 0x46
Parameter:
no
Reply (Byte 3):
decimal 89; hexadecimal 0x59
Parameter:
no
Example telegram
(in the example, the sensor has the address 1)
Master telegram
Designation
1. Byte
Address
2. Byte
Length
3. Byte
Command
4. Byte
Check sum
If output Q
is set to high after this command, the continuous transmission of measured values begins according to
1
parameter format data 4. No intervention is possible via the software during this time.
INFORMATION
This command must not be used in bus mode.
FT 50 RLA Disctance sensor - GB - 068-13671 - 19.05.2016-12
Decimal
Hex.:
129
81
4
04
73
49
76
4C
Decimal
Hex.:
129
81
4
04
70
46
67
43
Parameter format
12 bit data item:
Data 3 with switching output recognition
Sensor's reply telegram
Designation
1. Byte
Address
2. Byte
Length
3. Byte
Reply
4. Byte
Data
5. Byte
6. Byte
Check sum
Sensor's reply telegram
Designation
1. Byte
Address
2. Byte
Length
3. Byte
Reply
4. Byte
Check sum
Decimal
Hex.:
129
81
6
06
89
59
0
00
0
00
94
5E
Decimal
Hex.:
129
81
4
04
89
59
92
5C
75