Télécharger Imprimer la page

Balluff FT 50 RLA Serie Instructions De Service Et De Montage page 56

Publicité

Les langues disponibles

Les langues disponibles

No. Action
Picture
follows
20 „Maximum (Minimum)-Hold" (with Q
Q
Q
1
OK
I
C
FA
push
19x
21 „Difference hold" function (with Q
Q
Q
1
I
OK
C
FA
push
20x
22 Activate factory settings:
Q
Q
1
I
OK
C
FA
push
21x
56
Action
Reaction / Status indicator „ZA" (red)
as control input):
1
Switch with
ON, if maximum-hold active
2
OFF, if maximum-hold inactive
SET
If this function is activated and Q
determined and stored.
If Q
is low (-U
), the maximum value is transmitted at the analogue output.
1
B
Example of use: determining the maximum value of a shaft.
The minimum value can be determined by inverting the output characteristics (see func-
tion no. 16 and 17).
20 mA
4 mA
20 mA
4 mA
+U
B
Q
1
-U
B
A
as control input):
1
Switch with
ON, if difference hold active
2
OFF, if difference hold inactive
SET
When this function is activated and Q
maximum value of the measuring signal is determined and stored.
If Q
= -U
, the largest differential value is transmitted at the analogue output.
1
B
Example of use: Checking the contents of open containers or packages.
20 mA
4 mA
20 mA
4 mA
+U
B
Q
1
-U
B
B
Activate with
ZA lights up whilst the key is pressed
2
SET
SET
If the
key is pressed, all the settings are reset to the factory settings. This process
cannot be reversed.
= +U
, the maximum value of the measuring signal is
1
B
1
2
1
2
A
B
B
= +U
, the difference between the minimum and
1
B
2
1
2
1
B
A
B
A
FT 50 RLA Disctance sensor - GB - 068-13671 - 19.05.2016-12
operating instructions
Factory setting
Inactive
(„ZA" = OFF)
1
14 mA
2
8 mA
A
Q
= +
= Sample, collect measured values
U
1
B
B
Q
= -U
= Display, last maximum of
1
B
analogue signal at analogue output
Inactive
(„ZA" = OFF)
12 mA
1
2
2 mA
Q
= +U
= Sample, collect measured values
A
1
B
Q
= -U
= Display, last maximum of
B
1
B
analogue signal at analogue output.
--
Mounting and
Illustr. 17
15500153
Illustr. 18
15500149