8.5.4
Set Q
as Trigger input
1
Command (Byte 3): decimal 84; hexadecimal 0x54
Parameter:
no
Reply (Byte 3):
decimal 89; hexadecimal 0x59
Parameter:
no
Q
is set as trigger input. With rising edge on Q
1
Example telegram
(in the example, the sensor has the address 1)
Master telegram
Designation
1. Byte
Address
2. Byte
Length
3. Byte
Command
4. Byte
Check sum
8.5.5
Set Q
as control input for laser ON / OFF
1
Command (Byte 3): decimal 69; hexadecimal 0x45
Parameter:
no
Reply (Byte 3):
decimal 89; hexadecimal 0x59
Parameter:
no
Used to switch laser beam on and off. Laser beam is ON when Q
OFF. Last measured value remains. When reactivated, the response time is prolonged according to the set mean
value.
Example telegram
(in the example, the sensor has the address 1)
Master telegram
Designation
1. Byte
Address
2. Byte
Length
3. Byte
Command
4. Byte
Check sum
68
, measured value is held until the next trigger occurs.
1
Decimal
Hex.:
129
81
4
04
84
54
81
51
Decimal
Hex.:
129
81
4
04
69
45
64
40
Sensor's reply telegram
Designation
1. Byte
Address
2. Byte
Length
3. Byte
Reply
4. Byte
Check sum
= +U
. As long as Q
1
B
Sensor's reply telegram
Designation
1. Byte
Address
2. Byte
Length
3. Byte
Reply
4. Byte
Check sum
FT 50 RLA Disctance sensor - GB - 068-13671 - 19.05.2016-12
Mounting and
operating instructions
Decimal
Hex.:
129
81
4
04
89
59
92
5C
= - U
, the laser beam is
1
B
Decimal
Hex.:
129
81
4
04
89
59
92
5C