8.5.21
Change the sensor's address
Command (Byte 3): decimal 76; hexadecimal 0x4C
Parameter:
New address
Reply (Byte 3):
decimal 89; hexadecimal 0x59
Parameter:
no
Change in the address of the connected sensor.
Example telegram
(in the example, the sensor has the address 1, it is switched to 2)
Master telegram
Designation
1. Byte
Address
2. Byte
Length
3. Byte
Command
4. Byte
Data
5. Byte
Check sum
8.5.22
Read sensor settings
Command (Byte 3):
Parameter:
Reply (Byte 3):
Parameter:
76
Decimal
Hex.:
129
81
5
05
76
4C
2
02
74
4A
decimal 63; hexadecimal 0x3F
no
decimal 89; hexadecimal 0x59
Function 1
D8: Trigger input
D9: Q
is enable input
1
D10: X
D11: Maximum hold
D12: Difference hold
D13: Q
is software input
1
D14: fast measuring value output
D0: Q
is signal output
1
D1: Q
is scanning zone
1
D2: Q
is signal output inversion (1 = N.C.)
1
D3: Q
is signal output pulse stretching
1
D4: Minimum hold
D5: Autom. zero
D6: Autom. centre
Function 2
D8 ... D14: Identifikation of variants
D0: Q
is signal output
1
D1: Q
is scanning zone
1
D2: Q
is signal output inversion (1 = N.C.)
1
D3: Q
is signal output pulse stretching
1
D4: Q
ist good target output
2
D5 ... D6: X
Parameter format
7 bit data byte
Sensor's reply telegram
Designation
1. Byte
Address
2. Byte
Length
3. Byte
Reply
4. Byte
Check sum
Parameter format
Parameter format
12 bit data item: data 2
12 bit data item: data 2
FT 50 RLA Disctance sensor - GB - 068-13671 - 19.05.2016-12
Mounting and
operating instructions
Decimal
Hex.:
129
81
4
04
89
59
92
5C