Télécharger Imprimer la page

Balluff FT 50 RLA Serie Instructions De Service Et De Montage page 81

Publicité

Les langues disponibles

Les langues disponibles

Mounting and
operating instructions
12
Order information
Part no.
Part name
574-41018
FT 50 RLA-70-L8
574-41019
FT 50 RLA-70-S1L8
574-41034
FT 50 RLA-100-L8
574-41033
FT 50 RLA-100-S1L8
574-41014
FT 50 RLA-220-L8
574-41015
FT 50 RLA-220-S1L8
1
*
each include mounting and operating instructions FT 50 RLA (part no. 068-13671)
12.1
Accessories
Part no.
Part name
902-51646
L8FS-5m-G-PUR
902-51671
L8FS-2m-G-PUR
902-51687
L8FS-2m-W-PUR
902-51688
L8FS-5m-W-PUR
579-50000
MS F 50
579-50005
MSP F 50
533-11013
PC-SW ProgSensor
533-01005
CUSB-RS485-Set
533-11017
K2-ADE-TB
Accessories not included in delivery
INFORMATION
To operate the FT 50 RLA-S1 sensor on a PC, the PC must be equipped with a RS485 interface. If
this is not the case the existing interface (RS232, USB, etc.) can be used with a adaptor.
If your PC has a RS232 interface, we recommend to use the RS232 converter K2-ADE-TB *
If your PC has a USB interface, the additional CUSB-RS485-Set *
2
*
see accessory list for part numbers
INFORMATION
Data sheets, instruction manuals and operating software (Progsensor) are available for down-
load on www.sensopart.com.
FT 50 RLA Disctance sensor - GB - 068-13671 - 19.05.2016-12
Description
Distance sensor, 30 ... 100 mm, resolution 0.1 % of measuring range,
2 x PNP, N.O. / N.C., 4 ... 20 mA, M12 8-pin connector, *
Distance sensor, 30 ... 100 mm, resolution 0.1 % of measuring range,
2 x PNP, N.O. / N.C., 4 ... 20 mA, RS485, M12 8-pin connector, *
Distance sensor, 70 ... 170 mm, resolution 0.1 % of measuring range,
2 x PNP, N.O. / N.C., 4 ... 20 mA, M12 8-pin connector, *
Distance sensor, 70 ... 170 mm, resolution 0.1 % of measuring range,
2 x PNP, N.O. / N.C., 4 ... 20 mA, RS485, M12 8-pin connector, *
Distance sensor, 80 ... 300 mm, resolution 0.1 % of measuring range,
2 x PNP, N.O. / N.C., 4 ... 20 mA, M12 8-pin connector, *
Distance sensor, 80 ... 300 mm, resolution 0.1 % of measuring range,
2 x PNP, N.O. / N.C., 4 ... 20 mA, RS485, M12 8-pin connector, *
Description
Connection cable M12, 8-pin, length 5 m, straight, PUR
Connection cable M12, 8-pin, length 2 m, straight, PUR
Connection cable M12, 8-pin, length 2 m, angled, PUR
Connection cable M12, 8-pin, length 5 m, angled, PUR
Standard mounting bracket F 50 (V2A / 1.4301)
Mounting bracket F 50 (sensor protection V2A / 1.4301 / very robust)
Software
USB-RS485 interface converter, set incl. extension cable 0.7 m, CD-ROM
(driver-software) and D-SUB-socket CI D9F-S9 (9-pin, female) with screw
terminal
Interface Converter RS485/422 zu RS232
1
1
1
is required.
2
1
1
1
2
81