Mounting and
operating instructions
8.5.6
Averaging
Command (Byte 3): decimal 66; hexadecimal 0x42
Parameter:
Configuration
D0 = 1 : 0,4 ms (no averaging)
D1 = 1 : 4 ms (10 measured values)
D2 = 1 : 40 ms (100 measured values)
Reply (Byte 3):
decimal 89; hexadecimal 0x59
Parameter:
no
The measurement result (output signal) is smoothed by averaging. The measured values are continuously stored in a
memory and the mean value is formed. The number of measured values used for averaging is set here.
Example telegram
(in the example, the sensor has the address 1. Averaging is set to 4 ms.)
Master telegram
Designation
1. Byte
Address
2. Byte
Length
3. Byte
Command
4. Byte
Data
5. Byte
Check sum
8.5.7
Scaling analogue output (set 4 mA point)
Command (Byte 3): decimal 78; hexadecimal 0x4E
Parameter:
Data
Reply (Byte 3):
decimal 89; hexadecimal 0x59
Parameter:
no
The transmitted measured value becomes the 4 mA value of the analogue output.
Example telegram
(in the example, the sensor has the address 1)
Master telegram
Designation
1. Byte
Address
2. Byte
Length
3. Byte
Command
4. Byte
Data
5. Byte
6. Byte
Check sum
FT 50 RLA Disctance sensor - GB - 068-13671 - 19.05.2016-12
Decimal
Hex.:
129
81
5
05
66
42
1
01
71
47
Decimal
Hex.:
129
81
6
06
78
4E
63
3F
63
3F
73
49
Parameter format
7 bit data byte
Sensor's reply telegram
Designation
1. Byte
Address
2. Byte
Length
3. Byte
Reply
4. Byte
Check sum
Parameter format
12 bit data item: data 1
Sensor's reply telegram
Designation
1. Byte
Address
2. Byte
Length
3. Byte
Reply
4. Byte
Check sum
Decimal
Hex.:
129
81
4
04
89
59
92
5C
Decimal
Hex.:
129
81
4
04
89
59
92
5C
69