Télécharger Imprimer la page

Balluff FT 50 RLA Serie Instructions De Service Et De Montage page 52

Publicité

Les langues disponibles

Les langues disponibles

No. Action
Picture
follows
11 Set Q
as trigger input for sample and hold:
1
Q
Q
1
OK
I
C
FA
push
10x
12 Set Q
as control input for laser ON / OFF:
1
Q
Q
1
OK
I
C
FA
push
11x
13 Switch off averaging:
Q
Q
1
OK
I
C
FA
push
12x
14 Switch on 4 ms averaging:
Q
Q
1
I
OK
C
FA
push
13x
52
Action
Reaction / Status indicator „ZA" (red)
Switch with
ON, if Q
2
OFF, if Q
SET
With rising edge on Q
In master-slave operation, both sensors must be triggered.
Switch with
ON, if active
2
OFF, if inactive
SET
Used to switch laser beam on and off. Laser beam is ON when Q
the laser beam is switched OFF. Last measured value remains. When reactivated, the
response time is prolonged according to the set mean value.
Activate with
ON = averaging off
2
SET
Explanation of averaging:
Moving averaging „smooths" the measuring result (output signal) and enables the „mas-
king" of individual imperfections (e.g. when measuring objects with rough surfaces).
The measured values are read continuously into a memory and the arithmetical mean is
formed. Functions no.14 and no.15 determine the number of measurements (10 or 100) to
be used for averaging.
With a scanning rate of 0.4 ms per measurement, the response time lies between 0.4 ms
(without averaging) and 40 ms.
Response times
0.4 ms = measured value (no average) (function 13)
4 ms = averaging with 10 measured values (function 14)
40 ms = averaging with 100 measured values (function 15)
Switch with
ON, if active
2
OFF, if inactive
SET
The last (max.) 10 measured values are used to form the average. For an explanation on
„Averaging" see function no. 13
= trigger input
1
= not a trigger input
1
, measured value is held until the next trigger occurs.
1
Illustr. 12
Output characteristics in relation to arithmetical mean
15500273
FT 50 RLA Disctance sensor - GB - 068-13671 - 19.05.2016-12
Mounting and
operating instructions
Factory setting
Q
= no trigger input
1
(„ZA" = OFF)
„ZA" = OFF
= +U
. If Q
= - U
1
B
1
Averaging off
(„ZA" = ON)
Measuring object
Direction of movement
Response time
Averaging 4 ms OFF
(„ZA" = OFF)
,
B

Publicité

loading