Télécharger Imprimer la page

SICK GTB20 Manuel D'utilisation page 35

Masquer les pouces Voir aussi pour GTB20:

Publicité

Les langues disponibles
  • FR

Les langues disponibles

  • FRANÇAIS, page 69
5.5
AC/DC Devices
8026846.1LP5/2024-05-06 | SICK
Subject to change without notice
Table 8: Push-pull, PNP, NPN
PNP
Push-pull
NPN
PNP
Push-pull
NPN
U
: 21.6 V ... 253 V AC/DC, Rated insulation voltage U
B
Utilization category: AC-15, DC-13 (EN 60947-1),
CAUTION
Devices produced after 18 Jun 2023, beginning with date code 2325: Provide
suitable arc suppression for inductive or capacitive loads. Relay contacts are
separated from the supply voltage by an isolation of 5 mm.
Devices produced before 18 Jun 2023, with a date code of 2324 and earlier:
Provide suitable arc suppression for inductive or capacitive loads. Relay contacts
are separated from the supply voltage by a basic isolation of 3.2 mm. Depending
on the application, additional isolation might have to be applied in the user's
circuit.
Gxx20x-3A: Provide suitable arc suppression with inductive or capacitive loads.
Relay contacts are separated from the supply voltage by a base insulation of
3 mm. Depending on the application, additional insulation might have to be
applied in the user's circuit.
+ (L+)
Q ≤ 100 mA
Push-pull
‒ (M)
+ (L+)
Q ≤ 100 mA
Push-pull
‒ (M)
i
see "Technical data", page 42
O P E R A T I N G I N S T R U C T I O N S | GTB20
OPERATING INSTRUCTIONS
+ (L+)
PNP
Q ≤ 100 mA
NPN
‒ (M)
+ (L+)
PNP
Q ≤ 100 mA
NPN
‒ (M)
250 V, overvoltage category II,
en
35

Publicité

loading