8026846.1LP5/2024-05-06 | SICK
Subject to change without notice
6.
Tighten the M3 screw with a torque of 0.6 to 0.8 Nm.
7.
Seal the other opening with the plastic nut (with rubber) provided in the package.
C1, C2, C3
ØD
Table 3: Connection values, 1
B
1
2
3
4
5
Table 4: Connection values, 2
C1, C2, C3
C1 (PVC)
C1 (PUR)
C2 (PVC/PUR)
C3 (PVC/PUR)
CAUTION
Only switch on the voltage supply once all electrical connections have been established
and the terminal chamber has been properly secured.
Explanation of the connection terminology used in the following tables:
BN = Brown
WH = White
BU = Blue
BK = Black
GY = Gray
N. C. = Not connected
1
52 mm
47 mm
37 mm
32 mm
27 mm
Ø D [mm]
5.8 ... 6.7
5.8 ... 6.7
6.8 ... 7.7
7.8 ... 8.2
O P E R A T I N G I N S T R U C T I O N S | GTB20
OPERATING INSTRUCTIONS
1
2
2
63 mm
58 mm
48 mm
43 mm
38 mm
Torque [Nm]
1.3 ... 1.5
1.5 ... 1.7
1.7 ... 2.0
1.7 ... 2.0
en
3
33