Press the "mute" button to turn the alarm off and wait 12 hours for the
temperature to stabilize. If the set temperature has not been reached within this
time, please contact our technical service.
The following operating messages may appear on the thermostat.
Message
AFr
CHt
cht
dor
E1
E2
E3
E5
Ed1
H1
Lo
HA
HF
rsF
The operation of the equipment is controlled in its entirety by the digital
thermostat, which allows for the selection of the temperature and controls the
operation of the lighting (if any).
Connect the equipment to the mains. If "OFF" appears in the digital display, press
the ON/OFF button for 3 seconds.
The factory set point on positive refrigerated equipment is +2°C, and can be
adjusted on the thermostat between -2°C and + 8°C.
42
Description
Ice protection
Condenser high temperature alarm
Condenser high temperature warning
Open door
Problem probe 1 environment
Problem probe 2 evaporator
Problem probe 3 condenser
Problem probe 5
Defrost terminated after maximum time
High temperature
Low temperature
High temperature alarm during operation
High temperature alarm after power outage
Gas leak alarm
4.1.3. DIXELL
XR60CH / XR70CH