The operation of the equipment is totally controlled by the digital thermostat,
which allows for the selection of temperature and controls the operation of the
lighting using the button ( models with glass door and opaque door with lighting).
Connect the equipment to the mains. If "OFF" appears in the digital display, press
the ON/OFF button for 3 seconds.
The factory set point in positive refrigerated equipment of Simplify range is +3°C,
and can be set on the thermostat between + 1°C and + 8°C.
In the negative cold models of Simplify range, the factory set point is -20°C, and can
be adjusted in the thermostat between -16°C to -22°C.
In sub-zero models, the factory set point is -1°C, and can be adjusted between -3°C
and + 10°C.
The ACE 66 model, developed as a glass freezer, has a factory set point of -10°C,
allowing the temperature to be regulated between -8°C and -12°C.
In ACE 150 models with a glass door, the factory set point is -18°C, allowing the
temperature to be regulated between -16°C and -20°C.
In the backbar coolers, the factory setpoint is +3°C, and can be adjusted on the
thermostat between +2°C and +8°C.
The factory setpoint in the positive cold equipment and opaque door of the
Professional range is +3°C and can be adjusted on the thermostat between -2°C and
+8°C. In the glass door references, the thermostat can be adjusted between +1°C
and +8°C.
In the negative cold models of the Professional opaque door range, the factory
setpoint is -20°C and can be set from -15°C to -25°C. In the glass door versions, the
temperature can be set between -15°C and -22°C.
The thermostat is locked at the factory, allowing only the set point to be adjusted.
To do this, press the "Set" button, after the set value starts blinking, get to the
desired value with the "" ▲" and " ▼" buttons and press the "Set" key again to set
the value.
The temperature shown on the display is the equipment's internal temperature.
The equipment's noise level is less than 70dB.
Note: The equipment's difference in temperature (difference between maximum and
minimum permissible temperature) is set at 3°C at the factory for the refrigerated counters
and backbar coolers, in models ARV 800, BRS, BRG, BPP, BPG, and FGB, the difference is
4°C, and in models ARV 36; ARV 66, ARV 150, ARV 350, and ARV 450 the difference is 2°C.
When fully loading the cabinet, it is possible for the alarm to go off after 2 hours if
it has not reached the set temperature, and "Hi" is visible in the display.