With this command, the equipment has its own characteristics:
- A day and night mode (ENS/ECO night mode visible on the display). Automatic
temperature adjustment for energy saving without the need to follow the common
practice of turning the equipment off;
- The products are preserved, for example, at four (4) degrees during the day and
at 7 degrees overnight, according to factory setting;
- The lights and the power saving mode are set to switch on and off according to
the time the door is kept closed. There is, however, a lighting button if you prefer
to keep the light always on;
- Optimization of automatic defrost;
- Reducing power consumption by stopping the fan when it is not needed;
- Adjustable cabinet temperature;
- The automatic detection of ice in the evaporator and detection of lack of gas.
4.1.2. CAREL IJF
The operation of the equipment is totally controlled by the digital thermostat,
which allows for temperature selection and controls the operation of the lighting
(if any).
Connect the equipment to the mains. If OFF appears (cabinet off) in the display,
press
until --- appears in the display to unlock the thermostat, press
appears (cabinet on).
To change the Setpoint:
Press
until --- appears on the Display to unlock the thermostat;
Press SET and the current Setpoint appears, to change the temperature,
press:
SET to go up or
confirmed, the temperature entered will not be recorded).
Turn on/off light
Press
to go down and confirm with the key
until --- appears on the display to unlock the thermostat;