5.2 Installation instructions for anchor point SKYLOTEC Secupin SPA-TYPE-6-L
with cellular concrete dowel PBD M10x10-E A4
1
2
3
4
6.
IDENTIFICATION
All system components of the Secupin fall protection system are identified with the manufacturer's logo and the
necessary information for each user. Each SECUPIN anchor point carries the manufacturer's logo and serial
number on rod or tube.
Before installing the anchor eyelet AP-068-3 or AP-068-2, the correct number of users per installation instructions
must be entered with an X in the provided identification field with a letter punch. Thereafter, the anchor eyelet
contains all necessary information for the user and may be installed.
MAT-MA-0019-EN SECUPIN
Please observe installation instructions and approval (Z-21.1-
1525) of fasteners.
Drive in threaded conical bolt with setting tool without pre-drilling.
Fit expansion sleeve with slits facing the base.
Drive in expansion sleeve flush with setting tool.
Install single anchor point and apply torque of 8 Nm with calibrated
torque spanner.
23/01/2015