5.
INSTALLATION INSTRUCTIONS
Components necessary for installing a Secupin in cellular concrete. Required fasteners
for installation are supplied with the product. The following required components are not
included:
hammer drill
concrete drill (please observe the information in the fixtures' assembly instructions)
blow-out pumps for drill hole cleaning (Würth item no. 0903 990 001)
cleaning brushes
calibrated torque spanner
ratchet spanner and diverse bits from SW 13-19.
hammer
special setting tool for cellular concrete anchor (Skylotec part no. ACS-0180) or
machine setting tool (Skylotec part no. ACS-0203)
calibrated torque spanner
Special note:
The minimum strength class of cellular concrete must be 3.3 and the concrete must have a minimum thickness
of 175 mm.
5.1 Anchor point SKYLOTEC Secupin SPA-TYPE-6-L consisting of SPS-20-
02-300/400/500 and anchor eyelet AP-068-3 installed with cellular concrete
dowel PBD M10x10-E A4
All dimensions in mm.
MAT-MA-0019-EN SECUPIN
23/01/2015
Page 4 of 16