Using the machine interface
COOLING UNIT
009
Thermal protection
POWER SOURCE
010
Thermal protection
Fan
011
Fan default.
TRIGGER
012
A trigger is being pressed
MOTOR
015
Unable to reach the required speed
Overload, please check your settings
019
Press and release the trigger to erase
Problem with welding start-up
020
Please check your welding parameters
Press and release the trigger to erase
USB overload
024
Disconnect your USB
An internal system error has occurred.
-
Please restart your product
-
Calibration error
-
The product's memory space is full.
File %s not supported
-
Err %d
Continue anyway?
-
Unable to write to USB stick
The USB stick is not recognised. The display of
-
step 5 of the update procedure does not appear
on the screen (see general instructions).
If an error code which is not listed appears or your problems persist, contact your distributor.
24
Wait a few minutes for the cooling unit to cool down.
Ensure that the recommended duty cycle for the selected welding
current used is not exceeded.
Ensure that air inlets and outlets are not obstructed.
Wait a few minutes for the power source to cool down.
Ensure that the recommended duty cycle for the selected welding
current used is not exceeded.
Switch off the power supply by unplugging the mains connector, and
check that the fan is not blocked.
Remove the torch and check to see if the message is still active.
Check that the «Gas purge / Wire feed» switch is not blocked..
Check that the trigger on the MIG/MAG torch is not blocked or stuck.
Check the pressure settings on the wire-feeding rollers.
Check that the welding wire is not blocked in the torch liner.
Check the power source settings and installation (welding wire, rol-
lers, gas, torch, etc.)
If the problem persists, update the software (via Planet GYS).
Check the power source settings and installation (welding wire, rol-
lers, gas, torch, etc.)
If the problem persists, update the software (via Planet GYS).
Change the USB stick.
Turn the product off and on again.
If the problem persists, update the software (via Planet GYS)
Recalibrate the welding cables («Calibration» menu)
Delete Jobs to free up internal storage space.
The data on the USB stick is corrupted. Check your data.
Free up some space on the USB key.
If the problem persists, change the USB stick..
1- Insert the USB key into its socket.
2- Turn on the power source.
3- Hold down on the HMI thumbwheel to force the update.