d) Level display in dB, dBm
The dB function enables conversion in dB or dBm while measur-
ing alternate voltages. After this function is activated, the respective
conversion value is displayed in the small upper display.
Confirm the functions "dB" or "dBm" in the submenu to display the
current voltage value in the large and the corresponding dB value in
the small upper display. The display shows the respective symbol
"dB" or "dBm".
While performing one of these functions, you can switch between
two functions with the navigation buttons.
Press the button "CANCEL" to deactivate this function.
The dB function is only available for alternate volt-
ages.
e) MAX / MIN / AVG function
The MAX/MIN function enables recording and displaying the maximum
and minimum values during measuring. When the "MAX/MIN" func-
tion is activated, either the max or min value or the average is dis-
played. The current measured value continues to be displayed in the
small upper display. The figure shows an example for the DC volt-
age measuring range.
Confirm the functions "MAX", "MIN" or "AVG" in the submenu to fixate
the current measuring range (autorange is deactivated). The display
shows the respective symbol "MIN", "MAX" or "AVG". The currently
measured value will be displayed.
While performing one of these functions, you can switch between
the three functions with the navigation buttons.
Press the button "CANCEL" to deactivate this function.
The MAX-MIN function is not available for all measur-