Scanning rate (duty factor)
Range
20.0% ~ 80.0%
Overload protection 1000 V
Sensitivity: 5 Vpp - 10 Vpp
Signal: rectangular (5 Hz to 10 kHz)
HFR (Low-Pass Filter)
Range
Identical
with ACV
Overload protection 1000 V, cut-off frequency: 800 Hz (-3dB)
Temperature
Range
-200,0 to +10,0 °C
+10,1 to +1200,0 °C
-328.0 °F ~ 50.0 °F
50.1 °F ~ 2192.0 °F
Overload protection 1000 V
Acoustic continuity tester
Test voltage
approx. 2.5 V
Overload protection: 1000 V, <50 Ω continuous sound.
Display area: 1000.0 Ω, test current max. 0.1 mA
Diode test
Test voltage
approx. ±2.5 V
Overload protection: 1000 V, test current max. ±0.5 mA, test frequency
ca. 35 Hz
64
Accuracy
± (0.13% + 10)
Accuracy
(1.3% + 8) at 40Hz ~400Hz
Accuracy
± (1.3% + 20)
± (1.3% + 10)
± (1.3% + 40)
± (1.3% + 20)
Resolution
0.1 Ω
Resolution
0.001 V