Télécharger Imprimer la page

Eurocave Compact 59 Serie Mode D'emploi page 40

Masquer les pouces Voir aussi pour Compact 59 Serie:

Publicité

Les langues disponibles

Les langues disponibles

10 - O
In the event of operating faults in your appliance, alarms will warn you of the type of problem encountered.
1- Temperature
If your cabinet's temperature stays at + or - 4°C (7°F) in relation to the set temperature for more than 24 hours, a
visual and sound alarm is triggered.
The icon
flashes and a sound signal alerts you.
• The sound alarm cuts out if one of the buttons is pressed,
• However, the icon stays displayed until the temperature has returned within the limits of + or - 4°C (7°F).
Check that (see temperature alarms chapter page 19):
- The door of the cabinet is closed the door seal is not damaged.
- You have not loaded a large number of bottles into your cabinet during the last few hours
- Once you have checked these points, if the alarm continues for a few days, there may be an
operating fault. In this case, please contact your dealer.
II- Temperature probes
In the event of a failure in the temperature measurement probes, the 2 displays shown opposite will light up
and flash in turn. The displays stay lit until the problem is solved
In this case, please contact your EuroCave dealer.
NB: Your cabinet is equipped with a frost prevention device to protect you in
the event of a cold circuit failure (see above chapter)
III- Lighting
In the event of a lighting failure, do not handle the casing or the diodes. Contact your dealer.
NB: In all cases, if you feel your appliance is not behaving normally, contact your dealer.
11 - T
1 temperature
V 059
V 159
1220
V 259
1780
Multi-temperatures
S 059
S 159
1220
S 259
1780
Setting precision: +/- 1°C (2°F)- Display precision +/- 0.5 °C (1°F).
* 24H consumption measured with a solid door and an outside temperature of 68°F (20°C).
NOTE - The performance of cabinets equipped with glass doors may be sightly different in certain extreme conditions.
Your product conforms to the following standards:
1 SAFETY (article 3.1a of directive 1999/5/EC)
Standard(s)
2 EMC (Article 3.1 b of directive 1999/5/EC and additional requirements 89/336/EC)
Standard(s)
21
PERATING FAULTS
ECHNICAL SPECIFICATIONS
Size (mm)
H
W
D
(without handle)
820
594
566
594
566
594
566
820
594
566
594
566
594
566
EN60335-2-24
EN60371 Ed.02
EN55014-1/A1/A2Ed.00/01/02
EN55014-2/A1/A2Ed.97/02
*
or
.
Unloaded
Usage limits
weight (kg)
Min.T°
(C° / F°)
43
0/32
53
0/32
64
0/32
43
12/54
53
12/54
64
12/54
prolonged
N.B:
Only
exposure
to
excessive
temperatures
or
fluctuations in temperature
will harm your fine 'crus'.
Warning: Any intervention on
the cold circuit must be carried
out by a qualified expert who
should carry out a circuit
sealing check before starting it
up again.
In
the
same
way,
intervention on the electrical
circuit should be carried out by
a qualified electrician.
Consumption
Max.T°
per 24h*
(C° / F°)
(kWh)
35/95
0,40
35/95
0,45
35/95
0,49
35/95
0,35
35/95
0,40
35/95
0,45
violent
any

Publicité

loading