5. Remove the rear panel from the heat exchanger
(see Fig. 2, item 1).
6. Loosen the hexagon bolts (Fig. 2, item 2) and
(Fig. 2, item 3).
7. Mount the switch cabinet (Fig. 2, item 4).
8. Re-tighten the hexagon bolts (Fig. 2, item 2) and
(Fig. 2, item 3).
1
2
2.
1.
Fig. 2:
Assembly of switch cabinet
9. Re-attach the rear panel of the heat exchanger.
4.2
Splash guard housing
The splash guard housing protects the operator and his
surroundings from the consistently high test pressures
in the test system.
i
The splash guard can be used on both operator sides.
i
All housing sections are contained in parts
kit 1 688 039 046. The corresponding small
parts (screws etc.) are contained in parts kit
1 685 510 227.
i
We recommend installing the splash guard with 2
people.
Robert Bosch GmbH
4.2.1
1. Place the protective frame (Fig. 3, item 1) onto the
2. Affix the longitudinal members (Fig. 3, item 2) and
i
3
4
Fig. 3:
3. Place the protective frame (Fig. 4, item 1) onto the
4. Affix the protective frame to the longitudinal mem-
Fig. 4:
Installation | CRS 845H | 31
Assembly of front splash guard housing
EPS collector.
(Fig. 3, item 3) to the protective frame (Fig. 3, item 1)
using hexagon bolts M6 x 16 and washers (A6.4).
Do not screw in the rear hexagon bolt M6 x 16 (Fig.
3, item 4). This hexagon bolt will be fastened during
the later attachment of the rear splash guard housing.
X
X
3
Assembly of left protective frame
EPS collector.
bers using hexagon bolts M6 x 40 and washers A6,4.
Assembly of right protective frame
en
1
1.
2.
M6 x 16
4
M6 x 16
2
1
M6 x 40
A6,4
|
1 689 978 535
2014-10-21