Reset
Information
DMX FUNCTIONS
Enter MENU mode, select Address, press the ENTER button to confirm, use the UP/DOWN button to
select DMX Address, DMX Channel Mode or View DMX Value.
DMX ADDRESS
If you use a universal DMX controller to control the units, you have to set DMX address from 1 to
512 so that the units can receive DMX signals.
Press the MENU button to enter menu mode, select address, press the ENTER button to confirm,
use the UP/DOWN button to select DMX Address, press the ENTER button to confirm, the present
address will blink on the display, use the UP/DOWN button to adjust the address from 001 to 512,
and press the ENTER button to store. Press the MENU button back to the last menu or let the unit
idle 7 seconds to exit menu mode.
DMX CHANNEL MODE
To select DMX Channel Mode, press the ENTER button to show the DMX CHANNEL MODE on the
display. Use the UP/DOWN button to select Mode1 (15) or Mode2 (27), and press the ENTER button
to setup. Press the MENU button back to the last menu or let the unit idle one minute to exit menu
mode.
Please refer to the following diagram to set the DMX address for the first 4 units:
Channel Mode Unit 1 Address
15 channels
1
27 channels
1
VIEW DMX VALUE
To select View DMX Value, press the ENTER button to show the VIEW DMX VALUE on the display.
Use the UP/DOWN button to view the DMX channel values. Press the MENU button back to the last
menu or let the unit idle one minute to exit menu mode.
FIXTURE SETTING
Enter MENU mode, select Personality, press the ENTER button to confirm, use the UP/DOWN but-
ton to select Pan Inverse, Tilt Inverse, P/T Feedback, BL.O. P/T Moving, White Balance, Dimmer
curve, Fan speed, Factory default, Offset.
PAN INVERSE
To select Pan Inverse, press the ENTER button to show the PAN INVERSE on the display. Use the UP/
DOWN button to select No (normal) or Yes (pan inverse), press the ENTER button to setup. Press
the MENU button back to the last menu or let the unit idle one minute to exit menu mode.
TILT INVERSE
To select Tilt Inverse, press the ENTER button to show the TILT INVERSE on the display. Use the UP/
DOWN button to select No (normal) or Yes (tilt inverse), press the ENTER button to setup. Press the
MENU button back to the last menu or let the unit idle one minute to exit menu mode.
P/T FEEDBACK
To select P/T Feedback, press the ENTER button to show the PAN/TILT FEEDBACK on the display.
EN
6
Manual control
All
Pan/Tilt
Zoom
Fixture hours
Version
Unit 2 Address
Unit 3 Address
16
31
28
55
No
Yes
Unit 4 Address
46
82
© Copyright LOTRONIC 2020