Télécharger Imprimer la page

Flotec MULTIOIL Manuel D'utilisation Et D'entretien page 9

Publicité

Les langues disponibles
  • FR

Les langues disponibles

  • FRANÇAIS, page 13
WARNING
WARNING
Technical Data
Mains voltage / Frequency
Absorbed power
Type of protection
Suction fitting
Delivery fitting
flow rate
head
Maximum suction height including load losses
Power cable
Motor
Weight
Maximum dimension of pumped solid particles
Maximum admitted working pressure
Minimum ambient temperature
Maximum ambient temperature
Maximum temperature of the pumped fluid
Maximum number of starts per hour
Sound power level (Lwa)*
Sound pressure level (Lpa)
Sound emission values obtained in conformity with the EN 12639 standard
* Measurement method according to EN ISO 3746
Ch. 3 Installation (see Fig. 1)
DANGER
Electric shock
risk
WARNING
DANGER
DANGER
Use a suction pump (2) with a diameter equivalent to that of the suction mouth of the electropump (1).
If the height (HA) is over 4 meters use a tube with a larger diameter. The suction line should be perfectly airtight.
No elbows and/or slopes should be present to prevent the formation of air locks that could affect the electropump
efficiency. A foot valve (3) with filter (4) should be fitted at about half a metre below the fluid that has to be pumped (HI)
on one end of the line. Load losses can be reduced using delivery piping with a diameter equivalent or greater than the
electropump mouth (5). It is advisable to install a check valve (6) directly on the delivery line to prevent the electropump
being damaged by "water hammer".
Piping should be fitted so that vibrations, when existing, tension and weight do not affect the pump. Piping should be
routed along the shortest and straighter track, avoiding an excessive number of bends. Verify that the motor is properly
ventilated.
For permanent installations, it is advisable to fix the electropump to the supporting base, connect the system with a
section of non flexible pipe and insert a layer of rubber (or another anti-vibration material) between the supporting base
and the pump, in order to reduce vibrations.
The pump is not suitable for pumping salt water or dirty water for the supply of drinking
water, corrosive fluids or fluids containing abrasive materials (such as sand). Should
the pumped fluid contain sand or other abrasive particles, we recommend using a filter.
If used with tanks above 1000 litres, a trigger-type delivery gun must be used.
When installing, please ensure electropump is disconnected from electrical supply.
Pumps in this series are not suitable for use in a swimming pool and the relevant
cleaning and servicing operations.
Protect the electropump and all pipes from bad weather or freezing conditions.
This appliance can be used by children aged 8 years or over and by persons with limited
physical, sensory or intellectual capabilities, or with limited experience and knowledge,
provided that they are supervised or have been instructed in the safe use of the appliance
and are aware of the dangers involved. Children must not be allowed to play with the
appliance. Cleaning and user maintenance must not be carried out by children unless
they are supervised
To prevent possible injuries to people, avoid inserting hands into the mouth of the pump if
this is connected to the mains.
MULTIOIL
230 V ~ 50 Hz
550 Watt
IPX4
33,25 mm (1"F)
33,25 mm (1"F)
min. 300 l/h - max. 2.100 l/h
min. 4 m - max. 35 m
5 m with foot valve
H07RN-F
Single-phase, continuous-operation motor. External
ventilation, with condenser always ON
8,6 Kg
3 mm
6.5 bar
5° C
40° C
35° C in continuous mode
30 uniformly distributed
80 dB
68,6
2
GB
GB
7

Publicité

loading