Télécharger Imprimer la page

Flotec MULTIOIL Manuel D'utilisation Et D'entretien page 12

Publicité

Les langues disponibles
  • FR

Les langues disponibles

  • FRANÇAIS, page 13
GB
PROBLEM
THE PUMP DOES NOT DELIVER
ANY FLUID, THE MOTOR DOES
NOT RUN
THE MOTOR RUNS BUT THE
ELECTROPUMP DOES NOT
PUMP FLUID
THE PUMP WORKS BELOW
STANDARD
THE PUMP WORKS FOR A TIME,
THEN STOPS AS THE THERMAL
SWITCH TRIPS
If the problem persists despite the recommended corrective actions, contact the Customer Assistance Service.
Only for EU countries
Do not dispose of electric tools together with household waste material!
In observance of European Directive 2002/96/EC on waste electrical and electronic equipment
and its implementation in accordance with national law, electric tools that have reached the
end of their life must be collected separately and returned to an environmentally compatible
recycling facility.
10
POSSIBLE CAUSE
1) No power
2) Motor protection tripped
3) Defective condenser
4) Jammed shaft or impeller
1) The pump has not been primed
2) The check valve is not soaked in
pumped fluid
3) The pump sucks air in
4) There is air in the system
5) Clogged foot valve
6) The suction is placed too high
1) The suction pipe is too narrow
2) Dirty fluid
1) The power supply does not match the
rating value
2) The impeller is jammed by foreign
matter
3) Excessively thick fluid
1) Verify that voltage is present and that the plug
has been correctly inserted
2) Wait for the motor to cool down
3) Replace the condenser
4) Verify the cause and unblock the electropump
1) Prime the pump (see Sect. 5)
2) Soak the check valve
3) Make sure all joints are tightly sealed
4) Prime the pump again (see Sect. 5)
5) Clean the filter of the foot valve
6) Move the suction down
1) Use a larger diameter suction pipe
2) Clean the filter more often
1) Check the voltage of the power cable wires
2) Disassemble the hydraulics of the pump and
clean it thoroughly.
3) The pump is not fit for that use; use a different
type of pump.
5
GB
REMEDY

Publicité

loading