N
OTE:
The following procedure applies to both framed or frameless cabinet installations.
1 ] Run house power cable between service panel and hood location .
2 ] There are 2 pairs of recessed holes on each side of the top of the hood (on rear: A and B,
on front C and D on illustration below); these holes allow the range hood to hang on the
brackets (previously installed) .
HORIZONTAL EXHAUST INSTALLATION ONLY
3 ] Temporarily hang the hood on the brackets using its 2 recessed REAR HOLES (A and B) .
While holding the hood, run the house power cable into the hood through the strain relief
previously installed in step 6 on page 10 .
4 ] Unhook the rear holes from the brackets and hang the hood using its 2 recessed FRONT
HOLES (C and D) . While holding the hood, attach the power cable to the hood using the
strain relief .
VERTICAL EXHAUST INSTALLATION AND NON-DUCTED INSTALLATION ONLY
5 ] Hang the hood on the brackets using the 2 recessed FRONT HOLES (C and D) . While
holding the hood, run the house power cable into the hood through the strain relief
previously installed in step 6 on page 10 . Attach power cable to the hood .
6 ] Connect the ductwork to the hood and use metal foil duct tape to make joints secure and
air-tight . Make sure the damper assembly (or round duct plate) enters the ductwork and
that the damper opens and closes freely .
NOTE: See final installation steps on next page .
Install the Hood (EZ1 Bracket)
A
C
HD0846
A
HD0740
DUCTED INSTALLATION ONLY
D
B
B
15