EN
[3]. Connect the monitor wires to the 2 terminals on the rear le -hand
side of the door station:
- M+ of the monitor to M+ of the door station
- M- on the monitor to M- on the door station
Connect the electrical latch/lock wires to the + and - terminals on
the door station.
Connect the motorisation wires to the door station's dry contact
output (COM and NO).
Note: To feed the wires into the terminals, use a flat screwdriver to press
on the square with the notch, feed the wires in, then release.
[4]. The door station is supplied with the call button for 1 residence. If
the installation includes two separate residences, the switch at the
rear of the monitors must be positioned as shown in section "4.2
Installation for two residences" and the two call buttons supplied
with the kit must be used (see "5.2 Fitting the name plate").
[5]. Position the door station in the rain shield.
[6]. Secure the door station to the rain shield by tightening the screw
supplied using the Torx key.
10
Monitor cable
Gate motorisation cable
Copyright © 2018 SOMFY ACTIVITES SA. All rights reserved.
V300
Electric latch/lock
cable