3.3 Standard installation

3.3.1 For one residence
Distance between
the door station
and the furthest
monitor
Less than 50 m
A
Between 50 and
100 m
Less than 30 m
D
F
G
You are advised to use flexible cables and to tin the bare ends or fit them with end-pieces to be crimped.
The maximum wire section for the terminals is 1 mm².
Note: If you need to use junction boxes to cable the videophone, use no more than two boxes between the door station and the
monitor and no more than one box between the monitor and the mains adaptor.
6
Cable to be used
2 wires of min. 0.5 mm²
2 wires x 1 mm²
2 wires of min. 0.5 mm²
2 wires of min. 0.75
mm²
2 wires of min. 0.5 mm²
F
A
Optional
D
F
230 Vac
Copyright © 2018 SOMFY ACTIVITES SA. All rights reserved.
230 V AC
G
5 max.
230 V AC
G
5 max.
Note: We recommend that the
videophone cable and the motor
cable(s) be installed in separate
sheaths.