3.3.2 For two residences
The videophone V300 also offers you the possibility of configuring the interphone for two separate residences. In this case, the 2
residences must be cabled using a junction box installed on the 2 wires leading from the door station fitted with two call buttons (see
"4.2 Installation for two residences").
This configuration allows 1 additional monitor to be installed per residence.
Note: The monitor for the second residence is not provided in the initial pack.
Distance between the door station and the furthest monitor
Less than 50 m
A
C
B
Between 50 and 100 m
Less than 30 m
E
D
F
G
You are advised to use flexible cables and to tin the bare ends or fit them with end-pieces to be crimped.
The maximum wire section for the terminals is 1 mm².
Copyright © 2018 SOMFY ACTIVITES SA. All rights reserved.
30 max.
Optional
G
Optional
G
Note: We recommend that the
videophone cable and the motor
cable(s) be installed in separate
F
sheaths.
F
E
G
230 V AC
D
230 V AC
5 max.
230 Vac
C
230 V AC
B
G
230 V AC
A
Cable to be used
2 wires of min. 0.5 mm²
2 wires x 1 mm²
2 wires of min. 0.5 mm²
2 wires of min. 0.75 mm²
2 wires of min. 0.5 mm²