5. Anomalies de fonctionnement
Identifiez votre problème dans la colonne «constat» et suivez l'ordre des causes possibles.
CONSTAT
CAUSES
1.
POSITION DE LA CHICANE
2.
CHEMINÉE FROIDE
3.
CONDITIONS ATMOSPHÉRIQUES
REFOULEMENT À
L'ALLUMAGE
4.
LOCAL EN DÉPRESSION
5.
CHICANE MAL RÉGLÉE
6.
OBSTRUCTION DU CONDUIT
VÉRIFIER LES CAUSES: 1 - 2 - 3 - 4 - 5 - 6
7.
PASSAGE DES AMENÉES D'AIR DE COMBUSTION
TROP FAIBLE
LE FEU NE
DÉMARRE PAS
8.
COMBUSTIBLE D'ALLUMAGE INSUFFISANT
9.
HUMIDITÉ EXCESSIVE DU COMBUSTIBLE D'ALLU-
MAGE
VÉRIFIER LES CAUSES: 3 - 4 - 5 - 7
10.
HUMIDITÉ EXCESSIVE DU COMBUSTIBLE
LE FEU EST
11.
FAIBLE QUANTITÉ DE COMBUSTIBLE
DORMANT
12.
MAUVAISE QUALITÉ DU COMBUSTIBLE
13.
THERMOSTAT ENDOMMAGÉ
VÉRIFIER LES CAUSES: 3 - 5
14.
FORTE QUANTITÉ DE COMBUSTIBLE
LE FEU EST
15.
MAUVAISE QUALITÉ DU COMBUSTIBLE
TROP VIF
16.
AMENÉE D'AIR PARASITE
17.
FERMETURE DU THERMOSTAT ENTRAVÉE
VÉRIFIER LES CAUSES: 5 - 7 - 10 - 11 - 12 - 13
LA VITRE NOIRCIT
18.
PROPRETÉ DE LA VITRE AVANT MISE À FEU
19.
ENTRÉE D'AIR PARASITE
REMÈDES
•
LA REMETTRE CORRECTEMENT
•
PRATIQUER L'ALLUMAGE INVERSÉ, AVEC BEAUCOUP DE PETIT BOIS (VOIR CHAPITRE ALLUMAGE)
•
PRATIQUER L'ALLUMAGE INVERSÉ, AVEC BEAUCOUP DE PETIT BOIS (VOIR CHAPITRE ALLUMAGE)
•
ATTENDRE DE MEILLEURES CONDITIONS
•
AUGMENTER L'APPORT D'AIR DANS LE LOCAL (OUVRIR PORTE, FENÊTRE ET/OU ÉTEINDRE TOUT SYSTÈME D'ASPIRATION)
•
VÉRIFIER LA POSITION
•
FAIRE UN TEST À OUVERTURE MAXIMALE
•
PRÉVENIR L'INSTALLATEUR
•
APPLIQUER LE REMÈDE CORRESPONDANT
•
OUVRIR COMPLÈTEMENT LE THERMOSTAT
•
VÉRIFIER L'AMENÉE D'AIR EXTÉRIEUR
•
AUGMENTER LA QUANTITÉ
•
LE CHANGER PAR UN COMBUSTIBLE PLUS SEC
•
APPLIQUER LE REMÈDE CORRESPONDANT
•
AJOUTER DU COMBUSTIBLE PLUS SEC
•
AUGMENTER AU MINIMUM À LA CHARGE NOMINALE
•
UTILISER DU BOIS FENDU SANS ÉCORCE DE SECTION ADÉQUATE ET CORRECTEMENT DISPOSÉ
•
REMPLACEMENT PAR L'INSTALLATEUR
•
APPLIQUER LE REMÈDE CORRESPONDANT
•
RESPECTER LA CHARGE NOMINALE
•
UTILISER DU BOIS FENDU SANS ÉCORCE DE SECTION ADÉQUATE ET CORRECTEMENT DISPOSÉ
•
VÉRIFIER LA FERMETURE ET L'ÉTANCHÉITÉ DE LA PORTE DU FOYER
•
REMPLACEMENT PAR L'INSTALLATEUR
•
APPLIQUER LE REMÈDE CORRESPONDANT
•
NETTOYER SOIGNEUSEMENT LA VITRE
•
VÉRIFIER L'ÉTANCHÉITÉ DE LA PORTE