PARAMETER LIST
Parameter
Upper Pressure Setting (UPS)
Lower Pressure Setting (LPS)
Over Pressure
Service Factor Amps
Extended Run Time
Dry Run
Dry Run Delay
Dry Run Detection Time
Pressure
PN1053 (06-10-20)
All manuals and user guides at all-guides.com
DEVICE DETAILS
PRESSURE SETTINGS
PUMP START PRESSURE (CUT-
IN)
PUMP STOP PRESSURE (CUT-
OUT)
Update Value
Enter whole number between (Cut-In
+5) and 95
50
Submit
DRY RUN
ON
AUTO RESET DELAY (HH:MM)
DRY RUN SENSITIVITY
Figure 3: System Settings
Unit of Measure
Default
psi
50
psi
30
psi
80
A
-
Minutes
60
-
Enabled
Minutes
Seconds
30
psi
-
New users: Scroll down in the app and click SIGN UP AS
A CUSTOMER.
3.
Follow prompts to enter device and system information.
Complete online device registration.
The Pentek Well Defender' s unique device ID code is
required for this step and can be found on the inner
cover of the device itself.
30 PSI
50 PSI
Cancel
ON
Value
Min.
Max.
Sets the pressure for when the pump stops
10
90
running. Traditionally the Cut-Out setting.
Sets the pressure for when the pump starts
0
UPS - 1
running. Traditionally the Cut-In setting.
UPS + 5
100
Sets Over Pressure Fault value.
Service factor amps (max. load) of motor the
0
12
device is operating.
Number of minutes device can run before it
1
65000
faults on Extended Runtime.
Disabled
Enabled
Enables or disables Dry Run Detection.
Time device waits to restart pump when Dry
1
65000
Run is detected.
Time the device takes to recognize Dry Run
1
65000
condition.
Displays the actual system pressure at the
0
100
point of last data retrieval.
Description
7