Front - Bottom of Unit, See Detail B, Below
Fig. 9
Product Rating
Label/Serial Tag
3" Min.
36"
Power
Cord
Regulator (supplied
with unit) Install
horizontally, See
Detail B, Below .
3-Prong grounding
type receptacle
connected to
a properly grounded
and polarized
electrical supply rated
at 120VAC, 10 Amps,
Single Phase, 60 HZ.
Detail B – See Fig. 9, above
Suggested Regulator Installation
Installation Options
Installation Option 1. From Shut-off Valve
Manifold
3/4"
Regulator
Manifold
flex
adapter
3 / 4 "
flex
3/4" flex
line
adapter
Installation Option 2. From Manifold
Regulator
3/4" Manifold
Street
nipple
Ell 3/4"
3/4" x 3/4" x 3"
All manuals and user guides at all-guides.com
Step 2: Cabinet Preparation
Threading compounds must
be Resistant to Propane Gas
P24WOK 1/2" NPT
3/4" flex line
A manual valve must be
installed external to the
appliance, in an accessible
location from the front, for
the purpose of shutting off
the gas supply.
All Installer supplied parts must
conform to Local Codes.
Wall
gas flow
Shut-off
3 / 4 "
Valve
nipple
3/4"
Shut-off
flex
Valve
line
gas flow
3/4" flex
3/4" flex
adapter
adapter
gas flow
GAS SUPPLY REGULATOR
3/4 "
NPT
Outlet
Make sure gas
regulator is horizontal
after installation
7
Gas Flow
3/4 "
NPT
Inlet

Publicité

loading

Ce manuel est également adapté pour:

Pc36Pc48