Step 4: Gas Requirements and Hookup
CAUTION:
When connecting unit to propane gas, make
certain the propane gas tank is equipped
with its own high pressure regulator in addi-
tion to the pressure regulator supplied with
the appliance. The pressure of the gas sup-
plied to the appliance regulator must not
exceed 14" water column.
All manuals and user guides at all-guides.com
10
CAUTION
The appliance must be isolated from the gas
supply piping system by closing its individual
manual shut-off valve during any pressure
testing of the gas supply piping system at test
pressures equal to or less than 1/2 psig
(3.5kPa.).
"The appliance and its individual shut off
valve must be disconnected from the gas
supply piping system during any pressure
testing of the system at test pressures in
excess of 1/2 psig (3.5kPa.)."
When checking the manifold gas pressure,
the inlet pressure to the regulator should be
at least 6.0" W.C. for natural gas or 11.0" for
propane.
Do not attempt any adjustment of the pres-
sure regulator.