Safety Instructions; Connection - Weller DS 22 Manuel D'utilisation

Masquer les pouces Voir aussi pour DS 22:
Table des Matières

Publicité

Les langues disponibles
  • FR

Les langues disponibles

1. Safety instructions

The manufacturer assumes no liability for uses other than those described in the ope-
rating instructions, or for unauthorized alterations. These operating instructions and
safety instructions should be read carefully and kept in an easily visible location in the
vicinity of the soldering iron. Non-observance of these safety instructions can result
in accidents, injury or risks to health.
1. Caution, risk of burns!
Even after switch off or removal, the suction tip needs some time to cool down.
2. Always place desoldering tools not in use in the original holder.
3. Do not place any flammable objects near the hot desoldering tool.
4. Antistatic plastics are be treated with conducting material to prevent static char-
ging. This reduces the insulation properties of the plastic.
5. Work must not be performed on parts that are powered.
GB

2. Connection

Weller DS 22 and DS 22 antistatic can be connected to all electronically regulated
desoldering equipment with 50 W connectors.
The Weller DS 80 (UNC) and DSX 80 antistatic can be connected to all electronically
regulated desoldering equipment with 80 W connectors. To avoid the connection to
any less powerful controlunits, the DS 80 is equipped with a special 7 pin plug.
Technical Data
DS 22
Heating power:
Heating resistance:
Heating-up time:
Field of activity with Sn Pb 37/63:
Suction tiplet:
Wrench size:
DSX 80 / DS 80
Heating power:
Heating resistance:
Heating-up time:
Field of activity with Sn Pb 37/63:
50 W / 24 V~
10,5 ohm
< 100 sec. from 50°C - 350°C
270°C - 400°C
Thread M 5 / 12 - 24 UNC 2A
8 mm
80 W / 24 V~
6,2 ohm
~ 80 sec. from 50°C - 350°C
270°C - 450°C
5

Publicité

Table des Matières
loading

Ce manuel est également adapté pour:

Ds 80Ds 80 uncDsx 80

Table des Matières