placing in the holder. Do not use excessively aggressive fluxes.
The desoldering station has been set up for a medium size suction nozzle or soldering iron
bit. Temperature variations may occur if other bit shapes are used.
Important: Always ensure that the soldering iron bit is correctly seated.
External input unit WCB 1 and WCB 2 (optional)
The following functions are possible when using an external input unit.
Offset:
The real temperature of the soldering iron can be changed by ± 40°C
(72°F) by input of a temperature offset.
Setback:
Reduction of the required temperature set to 150ºC / 300ºF (standby).
The set-back time, the time after which the soldering station switches
into standby mode, can be adjusted from 0-99 minutes. The set-back
condition is indicated by a flashing actual value display. After a period
equal to three times the set-back time, „Auto-Off" is activated. The
soldering iron is switched off (flashing dash on the display). The set-back
or auto-off condition is ended by pressing a button or finger switch
pressure. During this process the required value set is briefly displayed.
Lock:
Locking the setpoint temperature. Settings cannot be changed after
the soldering station has been locked.
°C/°F:
Switching the temperature display from °C to °F, and vice versa.
Window:
Setting a temperature window (only with control units with optical coupler
output). If the actual temperature is within the temperature window, a
potential-free contact (optical coupler output) will be switched through.
Cal:
Re-adjustment of the soldering station (WCB 2 only).
PC interface:
RS232 (WCB 2 only).
Temp. gauge:
Integrated temperature gauge for thermal element Type K (WCB 2 only).
WDD 80V 07/00
27
PK Elektronik Vertriebs GmbH, E-Mail: info@pkelektronik.com, Internet: www.pkelektronik.com
5. Safety instructions
The manufacturer assumes no liability for uses other than those described in the operating
instructions, or for unauthorized alterations.
These operating instructions and warnings should be read carefully and kept in an easily
visible location in the vicinity of the soldering iron. Non-observance of these warnings can
result in accidents, injury or risks to health.
The WELLER soldering station WDD 80V is in compliance with the EC Declaration of Conformity
in accordance with the basic safety requirements specified by Directives 89/336/EEC and
73/23/EEC.
6. Accessories
5 13 500 99
Cleaning Tool
5 33 129 99
DS V 80 Desoldering Set UNC
5 13 191 99
DS 80 Desoldering Tool UNC
5 15 030 99
Holder AK 20
5 29 161 99
Soldering iron set WSP 80
5 33 111 99
Soldering iron set MLR 21
5 33 112 99
Soldering iron set LR 21, antistatic
5 33 113 99
Soldering iron set LR 82
5 33 133 99
Soldering iron set WTA 50
5 13 050 99
Reflow soldering unit EXIN 5
5 27 028 99
Preheating plate WHP 80
5 25 030 99
Thermal insulating unit WST 20
5 31 181 99
External input unit WCB 1
5 31 180 99
External input unit WCB 2
04.04.2002, 10:49 Uhr
27